• 269-Over-and-Under-3-Phase-Monitor

    EX269

    Over and Under 3-Phase Monitor

    The Model 269 Over and Under 3-Phase Monitor continuously monitors 3-phase lines for high voltage, low voltage, phase loss or phase reversal. This device features a solid-state voltage and phase-angle sensing circuit, which drives a SPDT output relay.

    The Model 269 is independent of the system load, and may be used on any horsepower motor. When phase sequence is correct, and the voltage remains between the upper and lower trip points, the output relay remains energizes. When a fault condition is sensed, the output relay drops out.

    The Model 269 does not require a neutral connection, and can be used on Wye or Delta systems. Each of the four voltage versions can be adjusted over a wide range. An adjustable trip delay (1-10 seconds) prevents nuisance tripping. OVER and UNDER voltage failure indicators aid in calibration and system troubleshooting.

    Select options
  • 269r-Over-and-Under-3-Phase-Monitor

    EX269R

    Over and Under 3-Phase Monitor
    Adj. Restart Delay

    The Model 269R Over & Under 3-Phase Monitor continuously monitors 3-phase lines for high voltage, low voltage, phase loss or phase reversal, and an adjustable . 3 – 5 minute restart delay. This device features a solid-state voltage and phase angle sensing circuit, which drives a SPDT output relay.

    The Model 269R is independent of the system load, and may be used on any horsepower motor. When phase sequence is correct, and the voltage remains between the upper and lower trip points, the output relay remains energized. When a fault condition is sensed, the output relay drops out.

    The Model 269R does not require a neutral connection, and can be used on Wye or Delta systems. Each of the four voltage versions can be adjusted over a wide range. An adjustable restart delay (0.3-5 minutes) allows compressor head pressures to bleed off, in the event of short-term power failures. OVER and UNDER voltage failure indicators aid in cali bration and system troubleshooting.

    Select options
  • 980535-Hold-Down-Clamp

    HDC-1

    Hold Down Clamp

    The Hold Down Clamp is constructed of stainless steel brackets and is joined with a rubber O-ring. The clamp is designed to secure the socket-mounted relay against vibration. The Hold Down Clamp is attached to the socket with existing mounting hardware. These clamps are made to fit all Time Mark and Signaline socket-mounted relays (Note: This product was previously designated as Model 98A535).

    Select options
  • 980544-Smart-Socket

    SS-480

    Smart Socket
    Type C - 480VAC

    Time Mark’s Smart Socket is the first socket which will allow monitoring of voltages up to 635 VAC with a socket-mounted Time Mark phase loss relay. The appropriate relay will allow monitoring for phase loss, phase reversal, low voltage and high voltage conditions. A key safety feature of the Smart Socket is it will not allow the voltage potential at the pin connections to rise to the full input voltage when the relay is removed. Two versions for the Smart Socket are available: one for 480 VAC and one for 575 VAC applications. The Smart Socket is designed to be used only with the Models B246, 253, 257B and 258B. Each of these relays is covered by Time Mark’s exclusive 5-Year Unconditional Warranty (Note: This product was previously designated as Model 98A544).

    Select options
  • 980544-Smart-Socket

    SS-575

    Smart Socket
    Type D - 575VAC

    Time Mark’s Smart Socket is the first socket which will allow monitoring of voltages up to 635 VAC with a socket-mounted Time Mark phase loss relay. The appropriate relay will allow monitoring for phase loss, phase reversal, low voltage and high voltage conditions. A key safety feature of the Smart Socket is it will not allow the voltage potential at the pin connections to rise to the full input voltage when the relay is removed. Two versions for the Smart Socket are available: one for 480 VAC and one for 575 VAC applications. The Smart Socket is designed to be used only with the Models B246, 253, 257B and 258B. Each of these relays is covered by Time Mark’s exclusive 5-Year Unconditional Warranty (Note: This product was previously designated as Model 98A544).

    Select options
  • TMC430-Pump-Controller

    TMC430

    Pump Controller

    The Time Mark model 430 pump controller is a versatile and advanced liquid level/pump management system. The Model 430 was designed to control up to three pumps with a 4-20mA input. It can also be used to control 2 pumps with a 4-20mA input and backup floats or to simply control two pumps with only float inputs. Alarm inputs are provided, if necessary, and may be disabled through the menu system if not used. Alarm inputs are: SF – seal fail, OT – over temperature, CF – contact failure, and SP – spare (eg. a second seal fail). A relay output is provided for the level alarm (either high or low), depending on pump configuration; PUMP UP or PUMP DOWN.

    Select options