• ENCDIN-11PIN

    Safety Enclosure with DIN Rail and One 11-Pin Socket

    The ENCDIN series of safety enclosures were designed to provide external protection for 8-Pin and 11-Pin socket-mounted devices such as: 3-Phase Monitors, Voltage Monitors, Current Monitors, Alternating Relays, Time Delay Relays, Liquid Level Controls, Transducers and Power Supplies.
    Each enclosure is made of 20 gauge steel with a dark gray powder coat finish. A standard 35mm DIN rail is attached inside with Time Mark’s 11-pin socket (rated 10A @ 300VAC) mounted to the DIN rail. Half-inch and three-quarter inch conduit knockouts are provided on three sides. The door is hinged to allow easy mounting and access.

    Select options
  • ENCDIN-8PIN

    Safety Enclosure with DIN Rail and One 8-Pin Socket

    The ENCDIN series of safety enclosures were designed to provide external protection for 8-Pin and 11-Pin socket-mounted devices such as: 3-Phase Monitors, Voltage Monitors, Current Monitors, Alternating Relays, Time Delay Relays, Liquid Level Controls, Transducers and Power Supplies.
    Each enclosure is made of 20 gauge steel with a dark gray powder coat finish. A standard 35mm DIN rail is attached inside with Time Mark’s 8-pin socket (rated 10A @ 600VAC) mounted to the DIN rail. Half-inch and three-quarter inch conduit knockouts are provided on three sides. The door is hinged to allow easy mounting and access.

    Select options
  • ENCDIN-8PIN-2

    Safety Enclosure with DIN Rail and Two 8-Pin Sockets

    The ENCDIN series of safety enclosures were designed to provide external protection for 8-Pin and 11-Pin socket-mounted devices such as: 3-Phase Monitors, Voltage Monitors, Current Monitors, Alternating Relays, Time Delay Relays, Liquid Level Controls, Transducers and Power Supplies.
    Each enclosure is made of 20 gauge steel with a dark gray powder coat finish. A standard 35mm DIN rail is attached inside with two of Time Mark’s 8-pin sockets (rated 10A @ 600VAC) mounted to the DIN rail. Half-inch and three-quarter inch conduit knockouts are provided on three sides. The door is hinged to allow easy mounting and access.

    Select options
  • EX158B

    3-Phase Monitor

    The Model 158 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 158 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electro-mechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset.

    The Model 158 does not require a neutral connection, and can be used with Wye or Delta systems. Four versions cover 120V, 208/240V, 480V (60Hz) and 380V (50Hz). Voltage ranges are sufficient to allow for proper adjustment to existing conditions. A front-mounted LED failure indicator is provided.

    The R versions of the Model 158 monitor have an additional LED indicator for RESTART and a 5 minute short cycle timer, to delay restarting the motor.

    Select options
  • EX158BR

    3-Phase Monitor
    5 Min. Time Delay

    The Model 158 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 158 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electro-mechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset.

    The Model 158 does not require a neutral connection, and can be used with Wye or Delta systems. Four versions cover 120V, 208/240V, 480V (60Hz) and 380V (50Hz). Voltage ranges are sufficient to allow for proper adjustment to existing conditions. A front-mounted LED failure indicator is provided.

    The R versions of the Model 158 monitor have an additional LED indicator for RESTART and a 5 minute short cycle timer, to delay restarting the motor.

    Select options
  • EX200

    3-Phase Voltage Unbalance Monitor

    The Model 200 3-Phase Voltage Unbalance Monitor is designed to continuously monitor a three-phase line for unbalanced voltage conditions.

    This device will only energize the relay if an unbalance exists. Zero volts on all three phases is considered a balanced condition. This allows the Model 200 to be used with shunt breakers, so that the breaker can shut off the main power without tripping the monitor.

    The solid-state sensing circuit drives an internal electromechanical relay. Indicator lights on the monitor show when the voltage balance is within an acceptable range; when an unbalance exists; and when the relay is actually tripped.

    When an acceptable voltage balance is reapplied, the Model 200 will automatically reset the relay.

    Select options
  • EX246

    3-Phase Monitor

    The Model 246 3-Phase Monitor is designed to continuously monitor 3-phase power lines for abnormal conditions. This device features solid-state voltage and phase angle sensing circuits, which drive a SPDT electromechanical relay.

    A neutral is not required, allowing the Model 246 to be used with either Wye or Delta systems.

    Three versions of the Model 246 cover the 120 and 208/240 VAC, 60Hz and the 380 VAC, 50Hz ranges. In addition, the models A246 and B246 are now CSA Certified.

    Each option on the Model 246 monitor is adjustable throughout its operating range. The adjustment pots and LED indicators of OVER VOLTAGE and UNDER VOLTAGE are mounted on the front of the unit, for easy access.

    Select options
  • EX252B

    3-Phase Monitor

    The Model 252 3-Phase Monitor continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 252 will detect phase loss on a loaded motor even when regenerated voltage is present.

    The device consists of a solid-state voltage and phase-angle sensing circuit, driving an electromechanical relay with one SPDT and one SPST contact. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected the Model 252 will automatically reset.

    The Model 252 does not require a neutral connection and can be used with Wye or Delta systems. Four versions cover 120V, 208/240V and 480V, 60Hz, and 380V, 50Hz. Adjustment ranges are sufficiently wide to allow for proper adjustment to existing conditions. Two LED indicator are provided to aid in adjustment and system troubleshooting.

    Select options
  • EX257B

    3-Phase Monitor

    The Model 257 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 257 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electromechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset (a manual reset version is also available).

    The Model 257 does not require a neutral connection and can be used with Wye or Delta systems. Voltage ranges are sufficiently wide to allow for proper adjustment to existing conditions. Both TRIP and NORM condition indicators are provided to aid in adjustment and system trouble-shooting.

    Select options
  • EX257B-415V/50HZ

    3-Phase Monitor

    The Model 257 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 257 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electromechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset (a manual reset version is also available).

    The Model 257 does not require a neutral connection and can be used with Wye or Delta systems. Voltage ranges are sufficiently wide to allow for proper adjustment to existing conditions. Both TRIP and NORM condition indicators are provided to aid in adjustment and system trouble-shooting.

    Select options
  • EX257BM

    3-Phase Monitor

    The Model 257 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 257 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electromechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset (a manual reset version is also available).

    The Model 257 does not require a neutral connection and can be used with Wye or Delta systems. Voltage ranges are sufficiently wide to allow for proper adjustment to existing conditions. Both TRIP and NORM condition indicators are provided to aid in adjustment and system trouble-shooting.

    Select options
  • EX257BM-415V/50HZ

    3-Phase Monitor

    The Model 257 continuously monitors 3-phase power lines for abnormal conditions. When properly adjusted, the Model 257 monitor will detect phase loss on a loaded motor even when regenerated voltage is present.

    This device consists of a solid-state voltage and phase-angle sensing circuit, driving an electromechanical relay. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize the relay. When the fault is corrected, the monitor will automatically reset (a manual reset version is also available).

    The Model 257 does not require a neutral connection and can be used with Wye or Delta systems. Voltage ranges are sufficiently wide to allow for proper adjustment to existing conditions. Both TRIP and NORM condition indicators are provided to aid in adjustment and system trouble-shooting.

    Select options