442-240
Multi-Stage AlternatorRead moreThe Model 442 Multi-Stage Alternator is designed to control the operating sequence of multi-stage motor/pumping systems. It can also be used to maintain the desired level of pressure-on air compressor systems. Four motor select DIP switches located on the front panel allow the alternator to control a single-motor/pump, two-motor/pump, three-motor/pump or four-motor/pump system. The Model 442 will assure that only the necessary motors/pumps are operating, and that the run time for each motor/pump is approximately equal. Motors are sequenced Sequence-On, Simultaneous-Off . If the motor/pumping demand requires only one motor/pump at a time, the alternator will start the next motor/pump in sequence each time an input switch is closed. Input switches may be float switches, pressure switches, flow switches, etc. , as required by the application.Potential uses for the Model 442 include water supply systems, sewage disposal plant systems, storage tank filling systems, air compressor systems, irrigation and water recycling systems.
-
448
Output Relay BoardRead moreThe Model 448 Output Relay Board provides electromechanical relay contacts for the Model 404 or 408 Liquid Level Sensors, allowing those models to be used as a control device. The Model 448 consists of a power supply and five relays on the surface-mounted printed circuit board. Four of the five relays are used with the Model 404. All five relays are used on the Model 408, refer to typical application. Some liquid level control applications may not require the alternating control, HOA switches, or run-time meters (see the Model 403 or Model 407 data sheets). The Model 404 and Model 408 Liquid Level Sensors uses the Model 448 to meet the needs of direct relay control applications. -
451
Pressure to Current Transducer0-15 psi input, 4-20mA outputRead moreThe Model 451 pressure transducer will convert 0-15psi to proportional 4-20mA signal. It can be used with any pump control system that utilizes a 4-20mA input for level control. The 451 can be mounted in a standard 8-pin octal socket for remote use. -
456-15
Pressure TransducerRead moreThe Model 456-15 Pressure Transducer is designed specifically to meet the rigorous environments encountered in many level measurement applications. This transducer provides repeatable, precise depth measurements under the most adverse conditions.It has been designed for installation in Class 1, Division 1, Groups A,B,C and D; Class II, Division 1, Groups E,F and G; Class III, Division 1 hazardous locations, when connected to the appropriate Stahl apparatus.
The Model 456-15 features high performance internal signal conditioning. An isolated diaphragm sensor has been incorporated for use with hostile fluids and gases. This sensor uses a silicon pressure cell that is fitted into a stainless steel housing with an integral, compliant stainless steel barrier diaphragm. The sensor assembly is housed in a rugged, compact 316 SS case, which provides for a variety of pressure inputs as well as electrical output connections.
-
460D
Switch-to-Loop Converter4-20mA loop outputRead moreLiquid level controllers generally require a 4-20mA loop current. The loop current indicates the level of liquid in a tank or reservoir, and is usually generated by an expensive pressure transducer or ultrasonic sensor. If you already have a tank with float switches installed, the Model 460D Switch-to-Loop Converter allows you to take advantage of the latest liquid level control, without the added cost of a transducer.
The Model 460D Converter outputs a specific current value as each of the six inputs are closed. Current values are individually adjustable between 4 and 20mA for each switch input. Up to six switches can be used as inputs to all liquid level devices accepting a 4-20mA input, such as Time MarkÕs Model 4052. -
51X016
11-Pin Socket10A@300VACRead moreThe Model 51X016 11-Pin Socket can be surface or DIN-rail mounted and is suitable for use up to 300 VAC. The thermoplastic body can withstand temperatures up to 300 F continuously without melting or electrical breakdown. Terminals are #6-32 screws, and are suitable for use with wire sizes up to two #12 AWG. The one piece molded body does not require a separate insulator strip.The Model 51X016 is UL Recognized, CSA Certified, and CE (European Conformity) Accepted.
-
51X120
8-Pin Socket10A@600VACRead moreThe Model 51X120 8-Pin Socket can be surface or DIN-rail mounted and is suitable for use up to 600 VAC. The thermoplastic body can withstand up to 300 degrees F continuously without melting or electrical breakdown. Terminals are #6-32 screws. The one-piece, molded body does not require a separate insulator strip. (Also known as 51012001.)UL Recognized file number E-126447, CSA Certification file number LR-29513-27M and CE (European Conformity) Accepted.
-
51X156
12-Pin Socket10A@600VACRead moreThe Model 51X156 is a 12-pin heavy duty socket and can be used with Time MarkÕs models 261XBXP and 261XBXPR Alternating Relays.Pressure clamp screws are #6-32 Zinc plated steel with a wire range of #12 to #22 AWG. Contacts are nickel plated brass. This socked is rated up to 600VAC and is UL Recognized and CSA Certified.
-
52901-02
3-Phase Fuse Block for Low Current Devices up to 600 VACRead moreThe fuse block is designed to provide fuse protection for low current (<3 Amp) 600VAC devices. Time Mark fuse blocks will accept 20mm or 32mm ceramic fuses for maximum flexibility. The fuse block includes three 20mm 1A fuses installed plus two spare fuses (SKU: 520078). Time Mark fuse blocks are available with screw terminals (-01) or FASTON 0.187 terminals (-02). -
553-01
Re-Acceleration RelayRead moreThe Model 553-01 Re-Acceleration Relay is designed to take the place of a voltage sensing relay and two time delay relays. When voltage is applied to the Model 553-01, and the external start switch is closed, the adjustable on-delay time begins. After the delay period, the contacts will close. If the line voltage drops below 90 volts, the contacts open and the true-off delay begins. If the voltage rises above 105 volts before the true-off delay has elapsed, the contact will re-close. If voltage is not restored to 105 volts before the true-off delay time period ends, the contacts will remain open until the external start switch is closed. -
553-02
Re-Acceleration RelayRead moreThe Model 553-02 Re-Acceleration Relay is designed to take the place of a voltage sensing relay and two time delay relays. When voltage is applied to the Model 553-02, and the external start switch is closed, the adjustable on-delay time begins. After the delay period, the contacts will close. If the line voltage drops below 90 volts, the contacts open and the true-off delay begins. If the voltage rises above 102 volts before the true-off delay has elapsed, the contact will re-close. If voltage is not restored to 102 volts before the true-off delay time period ends, the contacts will remain open until the external start switch is closed. -
553-03
Re-Acceleration RelayRead moreThe Model 553-03 Re-Acceleration Relay is designed to take the place of a voltage sensing relay and two time delay relays. When voltage is applied to the Model 553-03, and the external start switch is closed, the adjustable on-delay time begins. After the delay period, the contacts will close. If the line voltage drops below 90 volts, the contacts open and the true-off delay begins. If the voltage rises above 102 volts before the true-off delay has elapsed, the contact will re-close. If voltage is not restored to 102 volts before the true-off delay time period ends, the contacts will remain open until the external start switch is closed. -
553-04
Re-Acceleration RelayRead moreThe Model 553-04 Re-Acceleration Relay is designed to take the place of a voltage sensing relay and two time delay relays. When voltage is applied to the Model 553-04, and the external start switch is closed, the adjustable on-delay time begins. After the delay period, the contacts will close. If the line voltage drops below 90 volts, the contacts open and the true-off delay begins. If the voltage rises above 102 volts before the true-off delay has elapsed, the contact will re-close. If voltage is not restored to 102 volts before the true-off delay time period ends, the contacts will remain open until the external start switch is closed. -
553-05
Re-Acceleration RelayRead moreThe Model 553-05 Re-Acceleration Relay is designed to take the place of a voltage sensing relay and two time delay relays. When voltage is applied to the Model 553-05, and the external start switch is closed, the adjustable on-delay time begins. After the delay period, the contacts will close. If the line voltage drops below 90 volts, the contacts open and the true-off delay begins. If the voltage rises above 102 volts before the true-off delay has elapsed, the contact will re-close. If voltage is not restored to 102 volts before the true-off delay time period ends, the contacts will remain open until the external start switch is closed. -
64-5
Power Factor RegulatorRead moreThe Model 64-5 Power Factor Regulator is a monitoring and power factor control system. It is designed to help obtain an improved power factor, with a minimum of added capacitors. This device uses a unique phase-angle sensing circuit to monitor the power factor of a 3-phase power line. The Model 64-5 automatically responds to changing power factor by closing or opening the internal relays, which add or subtract capacitor banks on the line. Although intended for 115VAC 60Hz systems, other voltage or frequency models may be available. -
650-120-12
Loop Power SupplyInput: 120VAC Output: 12VDC regulatedRead moreThe Model 650 Loop Power Supply provides DC power for instrumentation control modules. Each option provides three output selections. For example the Model 650-240-24 has output options of 24 VDC regulated, 32 VDC unregulated, and 60 Hz pulse at 46 peak volts (See datasheet for all output selections).All outputs for the Model 650 are floating, electrically isolated from ground. A power status indicator (LED) is located on the top of the unit. The POWER LED comes ON when power is applied.
Applications for this device include two-wire current loop transducers, such as pressure, voltage or current. The Model 650 may also be used with alarm indicators, meters and timers.