3-Phase-Testers
Showing all 4 results
-

108C
Motor Rotation IndicatorRead moreRotating an electric motor shaft in the wrong direction can cause severe mechanical damage to expensive machinery. The Model 108C Motor Rotation Indicator can quickly show shaft rotation direction, thus becoming a valuable addition to your shop equipment. Designed of the installation of conveyer lines, pump systems and interconnected drives, the Model 108C requires only a few seconds to determine the proper connections to be made. The three leads are color coded: Red=phase A, Black=phase B, and White=phase C. This small device will allow you to connect all motors to run the proper direction. -

188
Phase Sequence DetectorRead moreThis compact handheld Phase Sequence Detector can help you quickly and easily verify the wiring on your 3-phase applications. Connect the Detector to any 3-phase circuit with nominal operating voltage from 188 to 660 volts (Wye or Delta with operating frequencies of 50, 60, or 400 Hz) and LED’s will indicate phase sequence (ABC or CBA), phases present or missing and 400Hz frequency. A Low Battery lamp is also provided to indicate when the 9V battery needs to be replaced. This unit is engineered and built in the U.S.A. and has a 5-year warranty. -

209-208/240V
Read moreThe Model 209 Line Voltage & Phase Sequence Detector can help prevent costly downtime and equipment damage by offering a quick and easy way to determine the phase sequence (ABC or CBA) and to check for missing phases in a 3-phase circuit. To use, connect the Detector to any 3-phase circuit, Wye or Delta. If all three phases are present and in the proper sequence, the ABC rotation lamp and the three line voltage lamps (A, B and C) will illuminate. An improper phase sequence will cause the CBA rotation lamp to illuminate. An open phase condition will cause both rotation lamps to flash and only illuminate two line voltage lamps. See the Condition Chart.The Model 209 is available in either a 208/240V option or a 480V option. Both models can be used in a three phase circuit with a frequency of 50Hz, 60Hz or 400Hz.
-

209-480V
Line Voltage and Phase Sequence DetectorRead moreThe Model 209 Line Voltage & Phase Sequence Detector can help prevent costly downtime and equipment damage by offering a quick and easy way to determine the phase sequence (ABC or CBA) and to check for missing phases in a 3-phase circuit. To use, connect the Detector to any 3-phase circuit, Wye or Delta. If all three phases are present and in the proper sequence, the ABC rotation lamp and the three line voltage lamps (A, B and C) will illuminate. An improper phase sequence will cause the CBA rotation lamp to illuminate. An open phase condition will cause both rotation lamps to flash and only illuminate two line voltage lamps. See the Condition Chart.The Model 209 is available in either a 208/240V option or a 480V option. Both models can be used in a three phase circuit with a frequency of 50Hz, 60Hz or 400Hz.