Products
Showing 337–352 of 661 resultsSorted by latest
-

301-H
Programmable Timer0.15 Sec. – 64 Min.Read moreThe Model 301 Programmable Timer is designed to replace over 100 standard timers. The Model 301 can be set for one of five functions, covers four timing ranges, and has a power supply for any AC/DC voltage from 10 to 28 Volts or 40 to 260 Volts. An SG version of this model is available using silver with gold flash contacts. The digital design of the Model 301 provides high accuracy, repeatability and response time. The output of the Model 301 is a heavy-duty DPDT electro-mechanical output relay. Programming options are chosen by simply setting the four DIP switches on top of the relay, and then adjusting a potentiometer for percent of delay. A LED indicator illuminates when the relay is energized. The Model 301 can be set to Delay-on-Release by adding an external jumper between pins 6 and 7 (see Installation Instructions).The Model 301 is UL Recognized and CSA Certified.
-

300-L
Programmable Timer0.15 Sec. – 64 Min.Read moreThe Model 300 Programmable Timer is designed to replace over 100 standard timers. One Model 300 can be set for one of five functions, covers four timing ranges, and has a power supply for any AC/DC voltage from 10 to 28 Volts or 40 to 260 Volts. An SG version of this model is available using silver with gold flash contacts. The digital design of the Model 300 provides high accuracy, repeatability and response time. The output of the Model 300 is a heavy-duty SPDT electro-mechanical output relay. Programming options are chosen by simply setting the four DIP switches on top of the relay, and then adjusting a potentiometer for percent of delay. A LED indicator illuminates when the relay is energized. The Model 300 can be set to Delay-on-Release by adding an external jumper between pins 6 and 8 (see Installation Instructions on product data sheet for more details).The Model 300 is UL Recognized and CSA Certified.
-

300-H
Programmable Timer0.15 Sec. – 64 Min.Read moreThe Model 300 Programmable Timer is designed to replace over 100 standard timers. One Model 300 can be set for one of five functions, covers four timing ranges, and has a power supply for any AC/DC voltage from 10 to 28 Volts or 40 to 260 Volts. An SG version of this model is available using silver with gold flash contacts. The digital design of the Model 300 provides high accuracy, repeatability and response time. The output of the Model 300 is a heavy-duty SPDT electro-mechanical output relay. Programming options are chosen by simply setting the four DIP switches on top of the relay, and then adjusting a potentiometer for percent of delay. A LED indicator illuminates when the relay is energized. The Model 300 can be set to Delay-on-Release by adding an external jumper between pins 6 and 8 (see Installation Instructions on product data sheet for more details).The Model 300 is UL Recognized and CSA Certified.
-

30
High Voltage Multi-Function Timer4 ranges (0.1 Sec. – 1023 Hr.)Read moreThe Model 30 is a High Voltage Multifunction Timer.
The digital design of the Model 30 provides high accuracy,
repeatability and response time. The output of the Model 30 is
a heavy-duty DPDT electro-mechanical output relay.
Four DIP switches select one of four timing functions and one
of four timing ranges. Delay time is set with a 10-position DIP
switch. When timing either the red LED will blink indicating the
relay is de-energized or the green LED will blink indicating the
relay is energized. On completion of the delay period either
the red LED lights indicating the relay is de-energized or the
green LED lights indicating the relay is energized.
600V operation is available, ask about the model 30-600. -

3PY-480
Transient/Surge Absorber3-Phase, 4-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PY-240
Transient/Surge Absorber3-Phase, 4-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PY-208
Transient/Surge Absorber3-Phase, 4-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PY-120
Transient/Surge Absorber3-Phase, 4-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PD-480
Transient/Surge Absorber3-Phase, 3-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PD-240
Transient/Surge Absorber3-Phase, 3-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PD-208
Transient/Surge Absorber3-Phase, 3-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

3PD-120
Transient/Surge Absorber3-Phase, 3-WireRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

1P-480
Transient/Surge Absorber1-PhaseRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

1P-240
Transient/Surge Absorber1-PhaseRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

1P-208
Transient/Surge Absorber1-PhaseRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage. -

1P-120
Transient/Surge Absorber1-PhaseRead moreTransient/Surge Absorbers (TSAs) provide system designers with a cost effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash, and near miss lightning strikes. There are 3 models available: single-phase (1P), 3-phase delta 3-wire (3PD), or 3-phase wye 4-wire (3PY). Each model is available to cover nominal AC voltages of 120, 208, 240 and 480. TSAs are designed using a ceramic and metal oxide technique which causes the resistance of the device to decrease abruptly if the rated voltage is exceeded. Voltage ranges are achieved by varying the types of oxide used in each model. Resistance changes are very fast, requiring less than 50 nanoseconds after the threshold voltage is exceeded. All models can repeatedly absorb in excess of 24,000 watt spikes without damage.

