Products
Showing 385–400 of 661 resultsSorted by latest
-

663
Pump Down ControlRead moreThe Model 663 Pump Down Control, part of the 600 series line of instrumentation controls, is designed to monitor and maintain liquid levels. A user-provided 4-20mA current loop represents the liquid level. The HIGH ADJUST setpoint, and the LOW ADJUST setpoint, are field adjustable. If the input rises above the high setpoint, the PUMP DOWN relay energizes, and remains that way until the input falls below the low set point. Top-mounted LEDs on the Model 663 show system status. The PUMP DOWN LED turns ON when the input is above the high setpoint, and goes OFF when the input is below the low setpoint. The HIGH ALARM condition indicator turns ON if the input rises to 10% above the high setpoint. The HIGH ALARM condition then resets when the input is again less than 10% above the high setpoint. For proper operation, the high setpoint must always be set above the low setpoint. An INPUT LOOP ERROR LED turns ON if the input is outside the 4-20mA range. A Time Mark Model 650 Loop Power Supply (or equivalent) is required to provide the 24 VDC operating voltage. Also, a Time Mark Model 672-15 Pressure Transducer (or equivalent) is required to provide the input signal. -

662
Pump Up ControlRead moreThe Model 662 Pump Up Control, part of the 600 series line of instrumentation controls, is designed to monitor andmaintain liquid levels. A user-provided 4-20mA current loop represents the liquid level, and output connections are provided for pump control. The HIGH ADJUSTsetpoint, and the LOW ADJUST setpoint, are field adjustable. If the input falls below the low setpoint, the PUMP UP relay energizes, and remains that way until the input rises above the high setpoint. The high setpoint must always be set above the low setpoint. Top-mounted LEDs on the Model 662 show system status. The PUMP UP LED turns ON when the input falls to 10% below the low setpoint, and resets when the input rises above this level. An INPUT LOOP ERROR LED turns ON if the input is outside the 4-20mA range. A Time Mark Model 650 Loop Power Supply (or equivalent) is required to provide the 24 VDC operating voltage.A Time Mark Model 672-15 Pressure Transducer (or equivalent) is required to provide the input signal.
-

451
Pressure to Current Transducer0-15 psi input, 4-20mA outputRead moreThe Model 451 pressure transducer will convert 0-15psi to proportional 4-20mA signal. It can be used with any pump control system that utilizes a 4-20mA input for level control. The 451 can be mounted in a standard 8-pin octal socket for remote use. -

448
Output Relay BoardRead moreThe Model 448 Output Relay Board provides electromechanical relay contacts for the Model 404 or 408 Liquid Level Sensors, allowing those models to be used as a control device. The Model 448 consists of a power supply and five relays on the surface-mounted printed circuit board. Four of the five relays are used with the Model 404. All five relays are used on the Model 408, refer to typical application. Some liquid level control applications may not require the alternating control, HOA switches, or run-time meters (see the Model 403 or Model 407 data sheets). The Model 404 and Model 408 Liquid Level Sensors uses the Model 448 to meet the needs of direct relay control applications. -

422
Submersible Pump ControllerRead moreThe Model 422 Submersible Pump Controller detects an overload or underload condition on all types of running pump motors: suction pumps, submersible pumps, etc. This Monitor detects the actual power used (voltage x current x power factor) and is more sensitive than simple current monitors. The 422 can be used with single phase pumps or, using the Model 276C current transducer, with 3-phase pumps. Matching CTs allow the Model 422 to be used with most pump motor sizes. Optional trip and restart delays are provided. -

409-24
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-

409-230
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-

409-120
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-

408-24
5-level Liquid Level SensorRead moreThe Model 408 is a 5-level liquid level sensor designed for use with bubbler-type systems. The 408 contains an internal air pressure transducer; the user must provide a small air compressor capable of supplying a maximum of 15 psi. This operates the system to a liquid depth of 34.6 feet. The output of the 408 connects to the inputs of the Model 407 3-Pump Liquid Level Controller (replacing the float switches) or to a Model 448 Output Relay Board. A 4-20mA signal output is provided as an input to process controllers or for other control applications. A 3-digit LED display continuously shows the liquid depth to 0.1 foot when the display control switch is in the Liquid Level position. Other switch positions allow setting of the corresponding trip level points. The trip points are set using coarse and fine adjustment pots, and are shown on the LED display. Each trip level has an LED indictor which illuminates as the solid-state output makes. A test feature allows the trip settings to be checked without actually changing the liquid level. -

408-115
5-level Liquid Level SensorRead moreThe Model 408 is a 5-level liquid level sensor designed for use with bubbler-type systems. The 408 contains an internal air pressure transducer; the user must provide a small air compressor capable of supplying a maximum of 15 psi. This operates the system to a liquid depth of 34.6 feet. The output of the 408 connects to the inputs of the Model 407 3-Pump Liquid Level Controller (replacing the float switches) or to a Model 448 Output Relay Board. A 4-20mA signal output is provided as an input to process controllers or for other control applications. A 3-digit LED display continuously shows the liquid depth to 0.1 foot when the display control switch is in the Liquid Level position. Other switch positions allow setting of the corresponding trip level points. The trip points are set using coarse and fine adjustment pots, and are shown on the LED display. Each trip level has an LED indictor which illuminates as the solid-state output makes. A test feature allows the trip settings to be checked without actually changing the liquid level. -

407
3-Pump Liquid Level Controller*** LIMITED QUANTITY AVAILABLE ***Read more***Limited Quantity Available*** (Ask about the new and improved 407D.)***LIMITED QUANTITY AVAILABLE***
The Model 407 3-Pump Liquid Level Controller provides central operating control of triplex pumping systems. The solid-state electronic controller provides alternating of load pumps, low level cutoff and high level alarm outputs. Runtime meters provide instant visual data on total running time of each pump motor. LED indicators show ON/OFF status of each pump. The 407 has five level-sense inputs which can be activated by float switches or other level sensing devices which provide a switch closure.
-

404-24V
Liquid Level SensorRead moreThe Model 404 Liquid Level Sensor operates in conjunction with a Model 403 Controller for bubbler-type duplex pumping systems. The 404 contains an air pressure-to-voltage transducer and requires only a small air compressor capable of 15 psi to operate the system down to approximately 35 feet. The Model 404s four outputs are designed to replace the float switch inputs to a Model 403, or to be used with a Model 448 output Relay Board. A 4-20mA signal output provides for other control applications. A 3-digit LED display continuously shows the liquid level to a tenth of a foot when the Display Control switch is in the Liquid Level position. Other settings of the switch allow setting of the liquid level trip points. LED indicators illuminate as the levels are exceeded. A test control allows the trip settings to be checked without actually raising or lower the liquid level. -

404-115V
Liquid Level SensorRead moreThe Model 404 Liquid Level Sensor operates in conjunction with a Model 403 Controller for bubbler-type duplex pumping systems. The 404 contains an air pressure-to-voltage transducer and requires only a small air compressor capable of 15 psi to operate the system down to approximately 35 feet. The Model 404s four outputs are designed to replace the float switch inputs to a Model 403, or to be used with a Model 448 output Relay Board. A 4-20mA signal output provides for other control applications. A 3-digit LED display continuously shows the liquid level to a tenth of a foot when the Display Control switch is in the Liquid Level position. Other settings of the switch allow setting of the liquid level trip points. LED indicators illuminate as the levels are exceeded. A test control allows the trip settings to be checked without actually raising or lower the liquid level. -

2744-24
3-Phase Over Current Monitor For Motor Jams1 – 5ARead moreThe Model 2744 3-Phase Over Current Monitor is designed to monitor the current level of a three-phase line or to compare the currents of three single-phase lines. If one or more current inputs rises above the trip level after the start delay has expired, the internal relay will de-energize. An adjustable start delay of 5 to 15 seconds will prevent nuisance tripping on start up. The current trip point is adjustable from 1 to 5 amps, and matching current transformers are available to extend the current range of the monitor. The Model 2744 will automatically reset when the current fault is corrected. An external manual reset can be added by installing a normally closed switch between the terminals marked RESET. -

2744-220
3-Phase Over Current Monitor For Motor Jams1 – 5ARead moreThe Model 2744 3-Phase Over Current Monitor is designed to monitor the current level of a three-phase line or to compare the currents of three single-phase lines. If one or more current inputs rises above the trip level after the start delay has expired, the internal relay will de-energize. An adjustable start delay of 5 to 15 seconds will prevent nuisance tripping on start up. The current trip point is adjustable from 1 to 5 amps, and matching current transformers are available to extend the current range of the monitor. The Model 2744 will automatically reset when the current fault is corrected. An external manual reset can be added by installing a normally closed switch between the terminals marked RESET. -

2744-120
3-Phase Over Current Monitor For Motor Jams1 – 5ARead moreThe Model 2744 3-Phase Over Current Monitor is designed to monitor the current level of a three-phase line or to compare the currents of three single-phase lines. If one or more current inputs rises above the trip level after the start delay has expired, the internal relay will de-energize. An adjustable start delay of 5 to 15 seconds will prevent nuisance tripping on start up. The current trip point is adjustable from 1 to 5 amps, and matching current transformers are available to extend the current range of the monitor. The Model 2744 will automatically reset when the current fault is corrected. An external manual reset can be added by installing a normally closed switch between the terminals marked RESET.