• 409-24

    Liquid Level Controller
    8-Pin, SPDT

    The Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.

    Requires a standard 8-pin octal socket. (socket number 51X00120-01)

    Select options
  • 4092-120

    Dual Seal Failure Detector

    The Model 4092 Dual Seal Failure Detector is designed specifically for monitoring the shaft seals of two submersible pumps. The probes are installed in the seal cavities of each of the pumps. When a seal begins to leak, contaminating fluid enters the seal cavity, lowering the resistance between the probe and the common connection. If the resistance drops below the sensitivity set-point, the corresponding relay and the LED indicator are activated. The Model 4092 will automatically reset when the fault condition is corrected. The sensitivity is field adjustable.

    Select options
  • 4092-240

    Dual Seal Failure Detector

    The Model 4092 Dual Seal Failure Detector is designed specifically for monitoring the shaft seals of two submersible pumps. The probes are installed in the seal cavities of each of the pumps. When a seal begins to leak, contaminating fluid enters the seal cavity, lowering the resistance between the probe and the common connection. If the resistance drops below the sensitivity set-point, the corresponding relay and the LED indicator are activated. The Model 4092 will automatically reset when the fault condition is corrected. The sensitivity is field adjustable.

    Select options
  • 4092I-120

    Isolated Dual Seal Failure Detector

    The Model 4092I Isolated Dual Seal Failure Detector is designed specifically for monitoring the shaft seals of two submersible pumps. All electrical inputs are totally isolated from each other. The probes are to be installed in the seal cavities of each of the pumps. The sensitivity is field adjustable. When a seal begins to leak, contaminating fluid enters the seal cavity, lowering the resistance between the probe and the common connection. If the resistance drops below the sensitivity set-point, the corresponding relay and the LED indicator are activated. The Model 4092I will automatically reset when the fault condition is corrected.

    Select options
  • 4093-120

    Liquid Level Controller

    The Model 4093 is a compact, socket mounted Liquid Level Controller that operates by monitoring the conductive liquid resistance between two probes. The unit monitors two liquid levels and responds as a pump-up or pump-down control as determined by the switch setting on the top of the unit. The green LED indicates pump operation while the potentiometer allows the user to adjust probe sensitivity.

    Select options
  • 4093-240

    Liquid Level Controller

    The Model 4093 is a compact, socket mounted Liquid Level Controller that operates by monitoring the conductive liquid resistance between two probes. The unit monitors two liquid levels and responds as a pump-up or pump-down control as determined by the switch setting on the top of the unit. The green LED indicates pump operation while the potentiometer allows the user to adjust probe sensitivity.

    Select options
  • 409D-120

    Liquid Level Controller
    11-Pin, DPDT

    The Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016).

    Select options
  • 409D-230

    Liquid Level Controller
    11-Pin, DPDT

    The Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016).

    Select options
  • 409D-24

    Liquid Level Controller
    11-Pin, DPDT

    The Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016).

    Select options
  • 410D-40J

    Auto-Charged Capacitor Trip Device
    40.4J of stored energy at 380V

    The 410D Auto-Charged Capacitor Trip Device is a micro-controller based high speed capacitor type circuit breaker tripping unit. It differs from standard CTD’s in that has a separate charging circuit and is isolated from the mains.
    This device is primarily for use with circuit breakers which require some form of AC power for their closing operation; i.e. circuit breakers having either a stored energy closing mechanism with an AC-operated release coil, or an AC solenoid-operated closing mechanism. The 410D-40J has a stored capacity of 40.4J at 380V and can maintain a full charge for 48 hours.

    Select options
  • 410D-80J

    Auto-Charged Capacitor Trip Device
    80.8J of stored energy at 380V

    The 410D Auto-Charged Capacitor Trip Device is a micro-controller based high speed capacitor type circuit breaker tripping unit. It differs from standard CTD’s in that has a separate charging circuit and is isolated from the mains.
    This device is primarily for use with circuit breakers which require some form of AC power for their closing operation; i.e. circuit breakers having either a stored energy closing mechanism with an AC-operated release coil, or an AC solenoid-operated closing mechanism. The 410D-80J has a stored capacity of 80.8J at 380V and can maintain a full charge for 48 hours.

    Select options
  • 412

    Automatic Reverse Controller

    The 412 Automatic Reverse Controller is a current sensor designed to detect jamming of sewage grinders and to initiate the reversing of the grinder. The controller allows the selection of up to five forward/reverse cycles, and provides for an alarm output, if the number of cycles is exceeded. The current loop inputs are designed for direct connection of 10 amps at 240 VAC, or 5 amps at 480 VAC (up to 2hp motors). For higher currents, a current transformer must be used (the CT secondaries are connected to the 5 amp terminals, regardless of voltage). A manual push-button is used to simulate an over current condition and to test the relay contacts and alarm. A current level adjustment is used to optimize the trip point setting. LED indicators show the running direction of the motor and the alarm condition.

    Select options