Liquid Level Controller
Showing all 11 results
-
403
Liquid Level ControllerRead moreThe 403 Liquid Level Controller provides central control of duplex pumping systems. The Model 403 includes pump alternating, visual run-time meters, hand-off-auto control and alarm outputs. Four level-sense inputs interface with float switches, pressure switches, or other level sensing devices which can provide a contact closure. -
4042
Liquid Level ControllerRead moreThe Model 4042 Liquid Level Controller monitors, displays and controls water level up to 34.6 feet, in a tank or reservoir. The Model 4042 operates from the 4-20mA input signal provided by the Time Mark Model 450 Pressure Transducer. This 4-20mA signal represents the water level to be controlled, where 4mA equals zero feet, and 20mA equals 34.6 feet. A liquid crystal display (LCD) is provided to show the water level during normal operations, and the set-point values during calibration. There are four user-adjustable trip set-points. As the water level rises above each trip point setting, the front panel LED for that level illuminates, and the corresponding output relay energizes. A 4-20mA output, which tracks the 4-20mA input, is also provided. This signal output can be rescaled to different ranges of level by the user. A test control, that stimulates an input signal, is available on the front panel. The test control is useful for checking the trip set-points, and overall system operation. -
4082
Liquid Level ControllerRead moreThe Model 4082 Liquid Level Controller monitors, displays and controls water level up to 34.6 feet in a tank or reservoir. The Model 4082 operates from the 4-20mA input signal provided by either the Time Mark Model 450 or Model 456-15 Pressure Transducer. This 4-20mA signal represents the water level to be controlled, where 4mA equals zero feet, and the 20mA equals 34.6 feet. A liquid crystal display (LCD) is provided to show the water level during normal operations, and the set-point values during calibration. There are eight user-adjustable trip set-points. As the water level rises above each trip point setting, the front panel LED for that level illuminates, and the corresponding output relay energizes. Two 4-20mA outputs, which track the 4-20mA input, are also provided. These signal outputs can be rescaled to different ranges of level by the user. A test control, that simulates an input signal, is available on the front panel. The test control is useful for checking the trip set-points, and overall system operation. -
409-120
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-
409-230
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-
409-24
Liquid Level Controller8-Pin, SPDTRead moreThe Model 409 is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, two-second time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting.Requires a standard 8-pin octal socket. (socket number 51X00120-01)
-
4093-120
Liquid Level ControllerRead moreThe Model 4093 is a compact, socket mounted Liquid Level Controller that operates by monitoring the conductive liquid resistance between two probes. The unit monitors two liquid levels and responds as a pump-up or pump-down control as determined by the switch setting on the top of the unit. The green LED indicates pump operation while the potentiometer allows the user to adjust probe sensitivity. -
4093-240
Liquid Level ControllerRead moreThe Model 4093 is a compact, socket mounted Liquid Level Controller that operates by monitoring the conductive liquid resistance between two probes. The unit monitors two liquid levels and responds as a pump-up or pump-down control as determined by the switch setting on the top of the unit. The green LED indicates pump operation while the potentiometer allows the user to adjust probe sensitivity. -
409D-120
Liquid Level Controller11-Pin, DPDTRead moreThe Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016). -
409D-230
Liquid Level Controller11-Pin, DPDTRead moreThe Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016). -
409D-24
Liquid Level Controller11-Pin, DPDTRead moreThe Model 409D is a compact, socket-mount device for level control of conductive liquids. The internal relay is energized when operating power is applied. When the liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will reset. A fixed, 300ms time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of a non-conductive material, a common electrode is required. Other features include an LED indicator to show the output relay status and an adjustable sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016).