261XBXPR-24
Alternating RelayRead moreThe Model 261XBXP(R) Alternating Relay uses the same solid-state latching and control circuit as all the other 261 series models, the enclosure and the connecting base being the major differences. This version was designed to replace a long time and widely used mechanical latching relay offered by another manufacturer. The modern circuitry used the Model 261XBXP offers a vast improvement in reliability and useful life over the mechanical type. The XBXP version of the relay requires closing the control switch to begin alternation, and the XBXPR version requires opening the control switch to begin alternation. Replacement of the original mechanical alternator with the Model 261XBXP requires the addition of wire from L1 to Pin 5 of the connector in order to supply continuous power to the solid-state circuit.Available in two voltage versions for use with 24 VAC/DC or 120 VAC/DC.
-
2621-110VDC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-120VAC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-12VDC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-208VAC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-220VAC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-240VAC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-24VAC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-24VDC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-28VDC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2621-48VDC
Pick Up/Drop Out Voltage MonitorRead moreThe Model 2621 dual set point voltage monitor is designed to monitor single phase equipment. The Normal LED indicates the relay is ENERGIZED. Toggle switch settings are as follows:Off lo
– Relay de-energizes at Lo Trip
– Relay energizes at Hi TripOn lo
– Relay energizes at Lo Trip
– Relay de-energizes at Hi TripThe Model 2621 is available in AC or DC versions. AC models of the 2621 are not frequency sensitive and can be used on systems from 50 to 400 Hz. Dual set points are ideal for battery charging applications.
-
2628
Over or Under Voltage MonitorRead moreThe Model 2628 AC/DC Voltage Monitor is designed to continuously monitor any AC or DC voltage from 15 to 260 volts.Input voltages below the set-point cause the output contacts to de-energize. Input voltages above the set-point cause the output contacts to energize. The dead band between pull-in and drop-out is less than 5%.
Dip switches are used on the Model 2628 to choose between AC and DC voltage monitoring, and to select one of the eight trip level ranges. Each trip level has a 35 voltage range, with a 5 volt overlap between the ranges. The unit has a screwdriver adjustment to set the exact trip point within that 35 volt range.
-
2629
Over or Under Voltage MonitorRead moreThe Model 2629 AC/DC Voltage Monitor is designed to continuously monitor any AC or DC voltage from 15 to 260 volts.Input voltages below the set-point cause the output contacts to de-energize. Input voltages above the set-point cause the output contacts to energize. The dead band between pull-in and drop-out is less than 5%.
Dip switches are used on the Model 2629 to choose between AC and DC voltage monitoring, and to select one of the eight trip level ranges. Each trip level has a 35 voltage range, with a 5 volt overlap between the ranges. The unit has a screwdriver adjustment to set the exact trip point within that 35 volt range.
-
268
Voltage Band MonitorRead moreThe Model 268 Over & Under Voltage Monitor is designed to ensure that the monitored operating voltage remains within a 120 VAC band. This device uses a dual op-amp comparator circuit to achieve stable and repeatable trip set-points.The output relay is energized only when the voltage being monitored remains between the upper and lower set-points. Voltages above or below the set-points will de-energize the relay, and illuminate the appropriate indicator LED.
The Model 268 Over & Under Voltage Monitor is designed for continuous duty operation.
-
2681-110VDC
Voltage Band MonitorRead moreThe Model 2681 Voltage Band Monitor is a dual set-point voltage monitor. Input voltages between the upper and lower set-points will cause the output contacts to pull in (contacts 1 & 3 closed) and the LED indicator to illuminate. Input voltages above or below the set-points will cause the output contacts to drop out (contacts 1 & 4 closed) and extinguish the LED indicator.The Model 2681 is available in AC or DC versions. AC models of the 2681 are not frequency sensitive and can be used on systems from 50 to 400 Hz. The voltage set-points are screwdriver adjustable over a wide operating range.
The SPDT output configuration is identical to the configuration of general purpose relays. This unit requires a standard 8-pin socket for mounting.
-
2681-120VAC
Voltage Band MonitorRead moreThe Model 2681 Voltage Band Monitor is a dual set-point voltage monitor. Input voltages between the upper and lower set-points will cause the output contacts to pull in (contacts 1 & 3 closed) and the LED indicator to illuminate. Input voltages above or below the set-points will cause the output contacts to drop out (contacts 1 & 4 closed) and extinguish the LED indicator.The Model 2681 is available in AC or DC versions. AC models of the 2681 are not frequency sensitive and can be used on systems from 50 to 400 Hz. The voltage set-points are screwdriver adjustable over a wide operating range.
The SPDT output configuration is identical to the configuration of general purpose relays. This unit requires a standard 8-pin socket for mounting.